Homelab Power Cost Calculator
What does it actually cost to run a server, NAS, or mini PC 24/7?
The sticker price on a used rack server or a new mini PC is only part of the decision. A device that idles at 150W instead of 15W will quietly cost you an extra $150-200 a year in electricity if it's on around the clock — often more than the hardware itself saved you up front. Plug in your own numbers below, or start from a preset for common homelab gear.
Your Setup
Leave this at 24 for something that's always on. Lower it if you only run the device part of the day.
Not sure of your rate? Check the cents-per-kWh line on a recent electric bill — the U.S. average is roughly 16-17¢/kWh, but it varies a lot by state and utility.
Estimated Cost
0 kWh/month at 65W, 24h/day. Estimate only — actual draw varies with load, and this doesn't include the cost of cooling the space the device is in.
Idle vs. Load: Why Your Actual Draw Matters
A server's power supply is rated for its worst case, not what it actually pulls sitting around waiting for work. Most homelab gear spends the majority of its time near idle, with short bursts under load. For a realistic number, run this calculator twice — once for your idle wattage across most of the day, once for load wattage across the busy hours — and add the two monthly totals together.
How to Measure What You're Actually Using
Don't guess if you don't have to. A cheap inline meter like a Kill-A-Watt gives you an exact reading for anything plugged into a wall outlet. A smart plug with energy monitoring (Kasa, Shelly, TP-Link) does the same thing and logs it over time. Enterprise gear with a BMC — iDRAC, iLO, IPMI — usually reports live power draw in its web UI or via ipmitool, no extra hardware needed.
Don't Forget Cooling
Every watt a server draws eventually leaves as heat, and if that heat is in an air-conditioned room, your AC has to work harder to remove it — a hidden cost this calculator doesn't include. Datacenters track this as PUE (Power Usage Effectiveness). For a single mini PC in a normal house it's usually negligible; for a rack of 2U servers running warm, it's worth factoring in, especially in summer.
Frequently Asked Questions
Quick answers on figuring out what your homelab gear actually costs to run.
Does this calculator account for idle vs. full-load power draw?
Not automatically — it assumes a single constant wattage for however many hours per day you set. Real servers and NAS units draw less power idle than under load, so for the most realistic number, run the calculator twice: once with your typical idle draw for the hours it's mostly sitting there, and once with load draw for the hours it's actually busy, then add the two monthly figures together.
What's a realistic average wattage for a mini PC, NAS, or rack server?
Very roughly: a mini PC (Intel NUC, Dell Micro) idles around 10-20W. A 4-bay NAS with spinning drives runs 40-60W. A small form factor desktop repurposed as a Proxmox node is usually 45-65W idle. A 1U rack server idles around 100-150W and can pull 250W+ under load. A 2U server or one packed with drives can idle at 150-250W. Actual numbers vary a lot by CPU, drive count, and PSU efficiency, so treat the presets above as a starting point, not a spec.
How do I find my actual electricity rate?
Check the per-kWh rate on a recent electric bill — it's usually listed in cents per kWh under supply or generation charges. The U.S. average is roughly 16-17¢/kWh, but this varies enormously by state and utility, from under 10¢ in parts of the Pacific Northwest and South to 30¢+ in California, Hawaii, and the Northeast. If your utility bills in tiers or has time-of-use pricing, use a blended average rate for a rough estimate.
Does this include the cost of cooling the room the server sits in?
No — this calculator only covers the electricity the device itself draws. If the server sits in an air-conditioned room, the heat it generates adds extra load onto your AC, which costs more electricity that this tool doesn't capture. That overhead (sometimes summarized as PUE, or Power Usage Effectiveness, in datacenters) matters more the hotter your climate and the more gear you're running — for one or two small devices in a normal house it's usually a minor factor, but a rack full of 2U servers in a warm garage is a different story.
Is an old enterprise server actually cheaper than a new mini PC once you account for power?
Often not, if it's running 24/7. A used 1U server drawing 150W costs roughly $175-215/year in electricity at the U.S. average rate, versus $15-25/year for a 15W mini PC — a gap of $150-200 every year the server is on. That can outpace the up-front savings of buying used enterprise gear within a year or two, especially for workloads (DNS, a reverse proxy, a small VM or two) that don't need server-class hardware. Enterprise servers still win on RAM capacity, PCIe lanes, ECC memory, and drive bays — just run the numbers on power before assuming used server hardware is the cheaper option overall. See the Enterprise Server Tracker for current used pricing.